Product News

Incandescent lamp energy efficiency standard inspection method in Taiwan

March 23, 2012, Taiwan area "issued by the Ministry of economy" to the 10104601990th announcement, to develop "energy efficiency standards for incandescent bulbs used inspection methods, and with immediate effect.

Announcement: first, the announcement of incandescent bulbs to comply with the standard CNS298 electric light bulb (general lighting) or CNS11006 family of small light bulbs specification, and rated power consumption of 25 or more Watt. Site articles are from the network.

A manufacturer, manufacture or import of incandescent bulbs, allow the consumption of energy efficiency benchmark management system shall submit the following documents provided to the central competent authority or its authorized agencies "(hereinafter referred to as management system) for the login account and password:

(a) management system login account and password application form.

(two) a copy of the certificate of registration of the company or the copy of the business registration certificate or the registration data of the above information system of the above competent authority. Copyright Disclaimer: the information provided by this site, if you need more detailed information, please contact our customer service.

Two, manufacturers to achieve management system login account and password, shall submit the following documents to the central competent authority for the products in accordance with the consumption of incandescent bulbs energy efficiency standards table approval: (a) the incandescent light bulb consumes energy efficiency standards for approval for examination and approval work table; entrust managers, the entrusted agent we should attach the principal manufacturers commissioned to produce the original certificate.

(two) the juridical person "TAF" approved with CNS3891 or CNS11006 detection ability of the laboratory to complete the incandescent light bulb and power consumption ratio of the initial beam performance test report issued by testing (to copy or electronic document CD with company seal mail the central competent authority).

The performance test report of the second paragraph mentioned in the preceding paragraph shall not be issued by the applicant or the laboratory owned by the company. If the application is approved by the central competent authority, the certificate of approval shall be issued.

At the beginning of three, before the provisions of the beam and power consumption ratio test, the same type of incandescent bulbs should be the initial beam were tested on 3 samples (in lumens, LM) and power consumption (in watts, W) and calculate the luminous efficiency (in LM / W, lm/W), and the average value of this type of luminous efficiency; the measured luminous efficiency up to the first decimal, second digits after the decimal point four to five homes. SEO sunflower collection of invincible pseudo original software is the only way to deal with pseudo.

Four. The type of the same paragraph referred to in the preceding paragraph shall be determined as follows:

(a) rated consumption of electrical power is different, depending on the type.

(two) the rated power consumption is the same, but the bulb diameter, the length of the bulb, the type of filling gas, the appearance (transparent, matte or film), filament material or shape is different, depending on the type.

(three) rated consumption of electric power, the diameter of the glass bulb, the length of the bulb, the type of filling gas, the appearance (transparent, matte or coating), filament material, filament shape, only the different types of lamp cap, as the same type.

Five, manufacturers or import incandescent bulbs have the following circumstances, should be re apply to the central authorities for approval: (a) product design changes, and the impact of its energy efficiency.

(two) the basic design of the product has not been changed, but the model has changed.

(three) when the energy consumption standards for products are revised.

Six, manufacturers should each year before the end of February, sales in a number of incandescent bulbs before completing the management system in the year.

Seven, the central competent authority to implement annual consumption of incandescent lamp energy efficiency of sampling inspection; the test samples shall be specified by the central competent authority, and by the production or import of manufacturers to within a specified time limit, the delivery of the juridical person "TAF" recognized with CNS3891 or CNS11006 detection ability the laboratory test.

The test samples, the measured luminous efficiency of incandescent lamp shall not be lower than the consumption of energy efficiency standards, and should be in the product labeling value above 95%; not met by the central competent authority informed the manufacturer for retest; retest number should be two times the number of samples of the same type of test, retest related expenses the burden of manufacturers.

Eight, the first point of the first test, according to the number of manufacturers or importers of the annual sales of incandescent bulbs in the proportion of the total number of measured, in principle, sales amounted to less than or up to 150 thousand, pumping a model. However, the central competent authorities can adjust the proportion of actual measurement..

Scan the qr codeclose