Many designs have clear solutions that are designed according to investment, energy and industry standards. Try to use conventional lighting unless special lighting is required on the project. Here we list some of the work standard information:
1, 2ft*4ft, with a thickness of 12 edges of organic glass mosaic lamp:
In various projects in the ceiling, lighting system is the most economical. This lamp can be equipped with two to three T8 fluorescent tubes and an electronic ballast. Can be used in computer.
2, 2ft*4ft, with a parabolic wide embedded grille lamp:
The lighting system is suitable for offices, shops and many other buildings in the ceiling. The luminaire shall be equipped with two to three T8 fluorescent tubes and an electronic ballast. Gsa separated columns should be equal to the number of light sources, their appearance is slightly better. In the use of computers, their lighting quality is at an acceptable low level.
3, surface sealed fluorescent lamps:
The lighting system is low cost and can be used for a variety of occasions and various ceiling system. This luminaire is usually equipped with two T8 fluorescent tubes and an electronic ballast, as well as a corrugated glass transparent cover. A workplace that is not suitable for use on a computer. Suitable for low ceiling places, their use is usually not higher than 10ft.
4, fluorescent band:
Lighting system with low cost this site can be used for building a variety of occasions, all kinds of ceiling and curtain box etc.. Under normal circumstances this lamp should be equipped with two T8 fluorescent tubes and an electronic ballast. In addition, they should be broken down into a single tube, double tube, end to end double tube (one after the first) and four tubes tied lamps. These lamps can be equipped with 4ft or 8ft fluorescent tube.
5, industrial fluorescent lamp:
The lighting system is low cost and can be used for a variety of occasions, usually used for general lighting without ceiling area. The lamp includes a double tube or four tube parallel lamp and an electronic ballast using 4ft or 8ft fluorescent tubes. The utility model can be matched with an integrated reflector, and a reflector with an upper opening and an upper lighting can also be used.
6, high intensity industrial gas discharge lamp:
The lighting system this low cost for medium or high altitude industrial plants (usually in the installation height of more than ft20ft), can also be used in gymnasium, warehouse and other large container open, with industrial characteristics of places. Pulse start metal halide light source capable of configuring multiple power.
7, industrial compact fluorescent lamp:
The lighting system this medium cost looks like industrial metal halide lamp under, but it uses multiple compact fluorescent lamp. They can be used in the installation height of not more than 30ft. Although the light effect is lower than that of the pulsed high intensity discharge lamp, the light source can be obtained by using the multi tube compact fluorescent lamp. The utility model has the advantages of quick start and can be used in groups, and a plurality of illuminance levels can be formed during the day or different use requirements.
8, indirect lighting suspension fluorescent lamp:
Fluorescent lighting system suspended from the ceiling, and provide lighting on the ceiling, usually using 4ft T5, T5HO or T8 light source, and the electronic ballast. They can provide a small amount of light below 10% of the total luminous flux. This type of luminaire must be suspended at least 18in below the ceiling, which requires a ceiling height of at least 9ft. These systems can be used as offices, classrooms, general lighting of some medical space, but also as office, retail stores and other shopping malls environmental lighting. It is believed that in the workplace where computers are used, they are good lighting fixtures. Low cost type lamps are made of steel plate, the more expensive and fashionable lamps are made of die cast aluminum. Can choose different light source combination, the most commonly used configuration is two or three T8 or T5 lamp or a T5HO light source. In continuous column installation, the spacing between the columns is about 10~12ft.
9, direct indirect lighting suspension fluorescent lamp:
The suspension type fluorescent lighting system can produce light and light, usually using 4ft T5, T5HO or T8 light source, and the electronic ballast. This type of luminaire must be suspended at least 12in below the ceiling, which requires a ceiling height of at least 9ft or higher. These systems can be used as offices, classrooms, general lighting of some medical space, but also as office, retail stores and other shopping malls environmental lighting. The use of computers in the workplace, they are suitable for lighting fixtures. Medium cost lamps are made of steel plate or plastic plate, and the more expensive and fashionable lamps are made of aluminum plate. The most advanced lighting technology using light guide. Can choose different light source combination, the most commonly used is two or three T8 or T5 lamp or a T5HO light source. When connected to the column, the column spacing is about 10~12ft.
10, embedded indirect lighting fixtures
This is a new product is very attractive, parabolic type lamp embedded type indirect lighting is slightly more expensive, can store, office and other places, often provide a brand-new appearance. However, it is possible to use them to create glare, which is not a good fit for open office space and other large studios. Size of 2ft*4ft model can use two or three fluorescent lamps.
11, embedded and ceiling mounted under the spotlight:
Also known under the spotlights downlight, is a great advocate for the appearance of lamps, corridors, halls, shopping malls and many occasions need the right amount of direct light masking. There are ten types of opening sizes ranging from 4~10in, including open reflector, open panel, adjustable light, transparent cover, decorative ring, etc.. The light emitting diode can be made of incandescent lamp or high efficiency compact fluorescent lamp and high intensity discharge lamp.
12, adjustable under the spotlight:
Is a kind of light, the use of PAR light and low power light source. It has important application in display lighting.
13, rail and ceiling type spotlight:
The display lights with various types, suitable for illuminating a single object. The appearance of the spotlight is like a tube, which can be used with compact fluorescent light source, MR16 low power light source, halogen tungsten PAR lamp and low power metal halide lamp.
14, track type, ceiling type and semi embedded wall lamp:
These display lighting lamp is applied to illuminate the surface of the object or as a display of lighting. They are usually installed in the ceiling or 12ft to the ceiling of the bottom, can illuminate a wall about 3~4ft wide. Optional light source includes high-power halogen tungsten lamp (100-500W), T5 double tube fluorescent lamp and metal halide lamp. Wall - to - wall lighting is an energy - intensive method of lighting, which is used only for surfaces that are really needed.
15, wall lamp:
Lamp is a kind of decorative lighting, can use incandescent and compact fluorescent lamp light source, it can produce attractive and highlight the effect of lighting, can be used in hotel, office building corridor, hall and many other places.
16, chandelier:
Chandelier is a decorative lamp from the ceiling hung, commonly used in shops, hotels, restaurants, their appearance and lighting effects are equally important. The design of the use of incandescent or halogen lamp light source, but compact fluorescent lamps, including the optional light source is also increasing.
17, ceiling lamp:
Ceiling is round or square lamp installed in the ceiling surface. They are often used in corridors, lounges, storage rooms, and many places where light is needed. The ceiling lamp is usually inexpensive and has a light shield or diffuser that surrounds and protects the light source. Ceiling lamp is practical, but also decorative, in the need to pay attention to the prevention of violence and destruction of the place, you can choose a durable ceiling lamp.
18, movable table lamp and floor lamp:
Table the traditional incandescent lamp, the lamp can also change now through the use of compact fluorescent light. The method of changing the fluorescent lamp in the traditional lamp is that the power of the fluorescent lamp can be obtained by dividing the power of the corresponding incandescent lamp by 3.5.
19, operating lighting fixtures:
Since several decades ago, the traditional architectural drawing lamp, lighting lamp flexible operation has become a practical and attractive tool.
20, cabinet lamp:
They are operation lamp. Cabinet lamp should be installed at the bottom of the leading edge of the cabinet, and should be kept on the whole length of the day. The use of fluorescent lamps is the highest energy efficiency, the lowest cost, but in many cases, the choice of high-grade types of tungsten halogen lamps and xenon lamp is also very good.
21, mirror headlights:
Is a kind of job for lighting, lavatory and mirror area. It can be installed horizontally above the mirror, or vertically mounted next to the mirror. The headlights can be highly decorative, but many types are practical and can be used elsewhere. The headlight can use incandescent lamp or halogen tungsten lamp, but fluorescent lamp is a better choice.
22, exit sign lamp:
Exit light can use energy-efficient light source. At present, most of the modern exit signs use the LED light source to illuminate the surface. However, in the case of the need for a higher surface brightness or the need to configure the light emitting lamp, cold cathode tube exit light can be considered. Other types of light sources, such as incandescent and compact fluorescent lamps, can also be used, but there is insufficient energy efficiency and longevity compared to LED or cold cathode tubes.
NVC lighting many varieties, fine materials, excellent quality, exquisite technology, elegant appearance, is the first choice for customers and decoration engineering. The Olympic projects, large-scale municipal projects, four or five star hotel, brand chain stores, supermarkets, offices, industrial lighting, city and road landscape, schools and libraries, exhibition halls, clubs, airports, gas station, hospital and family have used NVC lighting.